Mitr Phol Bio-Power (Kalasin) Co., Ltd.
|
Reduce energy intensity by 0.24%.
|
Insulating heater tanks, resulting in a reduction of heat loss by ~15 MMJ/year and a reduction of fuel consumption (bagasse) by ~2,015 tons/year
|
Energy intensity was reduced by 0.26%
|
Mitr Phol Bio-Power (Phu Khiao) Co., Ltd.
|
Reduce energy intensity by 0.95%.
|
Controlling bagasse humidity to below 47% before feeding it into the boiler, resulting in a reduction of heat loss by 24 MMJ/year and a reduction of fuel consumption (bagasse) by ~2,897 tons/year
Upgrading machinery to support the use of sugarcane leaves as a substitute for wood chips and other fuels, resulting in a reduction of energy loss by 95MMJ/year
|
Energy intensity was reduced by 1.07%
|
Power Prospect Co., Ltd.
|
Reduce energy intensity by 1%.
|
Adjusting the blade angle and reducing the frequency (Hz.) of the cooling fan, resulting in a reduction of the motor’s power consumption by 49,565.38 kWh/year
Adjusting the flow rate of the boiler feed pump, resulting in a reduction of power consumption by 267,519.31 kWh/year
Improving the fuel depot to lower fuel humidity (wood chips), resulting in a reduction of heat consumption by 18 MMJ/year, an increase in the fuel’s low heating value (LHV) by 0.43 MMJ/kg, and a reduction of fuel consumption by ~2,047 tons/year
Improving the fuel depot to lower fuel humidity (wood chips), resulting in a reduction of heat consumption by 18 MMJ/year, an increase in the fuel’s low heating value (LHV) by 0.43 MMJ/kg, and a reduction of fuel
consumption by ~2,047 tons/year
|
Energy intensity was reduced by 1.96%
|